e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service); +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
Revised 03/2006
S-311
1-39
WARNING! Before doing any adjustments, disconnect
the air supply and deflate the test of compressed air in the
machine.
The basic clamp plates adjustment ➊ with clamp feet ➋
is possible to modify after removing from the machine.
6.1. After loosening the screws ➌ adjust the clamp
feet➋ from front to rear (in the Y axis) and after
loosening the screws ➎ from left to right
(in the X axis)
6.2. The adjust feet ➋ clamp against the plates ➒ for
1,2 - 2,0mm overlap.
6.3. Remove the side table covers ➏ by removing the
screws ➐.
6.4. Insert the clamp plates ➊ into the machine.
6.5. Adjust the plates lift ➋ for 12mm and after
loosing the screws ➍ tighten them again.
6.6. Put the side table covers ➏ on and screw them.
6.7. Check the proper adjustment when sewing.
Recommended space between the clamp foot and
needle during the outer penetration is 1 mm. If the bite
size is changed, ensure this space by covering the clamp
feet ➋ over clamp plate ➒ - measure A to values. Adjust
after loosening the screw ➎ and shifting the clamp plate
arm to the correct needed clearance.