e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service); +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
Revised 03/2006
1-36
3. THE BEDPLATE HOME POSITION ADJUSTMENT
The bedplate home position is given by position of the plates Í,Ð and sensor BQ2 Ñ for axes X and
BQ3 Î for Y. Sensor plate screws are painted from the manufacturer, and only a service technician
from AMF REECE can perform this operation during the guarantee period .
3.1. Adjust the sensor plate Í (BQ2) Ñ after loosening the screws, Ì to approximately 14 mm.
Remove the right cover of the bedplate Ò to access to the plate Í.
3.2. After removing the left cover of the table Ê adjust the sensor (BQ3) Î. Loosen the screws Ï to
obtain the 129 ± 0.2 mm from the shaft holder Ë to the plate edge - see picture. Belt holder is
set to 138 mm from the shaft holder Ë. The plate Ð should be 32mm long.
3.3. The clearance between the sensor and plate must be 0.2 - 0.3mm. More clearance causes
improper sensor function.
3.4. Adjust the position of the sensor plate Ð if the dimension from inner puncture in the eye top
and the centre needle is not 64mm. Approximately 154mm from the adge of the bedplate, see
section E8).
E - STANDARD MACHINE ADJUSTMENT
138 mm
129 ± 0.2 mm
 
Vue de la page 47