Revised 03/2006
e-mail: service@amfreece.cz; parts@amfreece.cz; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
2-6
S-311
SYMPTOM POSSIBLE CAUSE PROBABLE SOLUTION
When sewing operation
started, motor does not
operate. Frequency inverter
U5 error - check its display -
does not light. Contactor KM1
switched on.
TROUBLESHOOTING
4. ELECTRICAL FAULTS
When switch in position I,
neither the work light or the
cooling fan operate
Check main power supply or
voltage in the socket
No power supply
SYMPTOM
POSSIBLE CAUSE
PROBABLE SOLUTION
The length of the buttonhole and the
length of a flybar is incorrectly set
Set correct length of a buttonhole
and length of a flybar - see section
D3. The total can not exceed 50.
After the machine is switched
on, display does not light
Fuse F4 failure (T10A)
Display or its control damaged
Cable from the display
disconnected
GS1, GS2 Power damaged
Relay VC1 damaged
The supply voltage is above
255 V (red LED lights on relay
VC1 — if there is the relay VC1)
Power switch QS1 damaged
Fuse F1, F2 failure (T2A)
Replace fuse PN 12.0008.4.664
Replace display or control units,
call AMF Reece Service
Check the display connection
Replace the power 12.0008.4.709
Replace the relay 12.0008.4.690
Call electronic engineer in the plant
Replace the switch 12.0008.4.835
Replace fuse PN 12.0008.4.665
Frequency inverter U5 error or
filter Z1 error
Call AMF Reece service
When sewing operation
started, motor fails to operate.
Frequency inverter U5 error -
check its display - does not
light. Contactor KM1 switched
off.
Fuse F3 failure Replace fuse PN 12.0008.4.063
Contactor KM1 damaged
Replace contactor 12.0008.4.833
Emergency stop turned off
Turn on emergency stop
Defective emergency stop button
Change the stop button
PN 12.0008.4.563
Disconnected girth
Check the girth button
Vue de la page 101