5. PARAMETERS SAVING
1. To save the set parameters to the same
assigned number of a buttonhole Ê,
press button Ë.
This appears on the display and parameters are saved.
2. To save the set parameters to a new number of a buttonhole: press the number
of a buttonhole button Ê.
The numerical display appears on the display.
Choose the number and press the button Ì.
The number of buttonhole Ê appears on the display.
Press button Ë, to save set parameters.
This appears on the display and parameters are saved.
D - MACHINE CONTROLS
4. THE SEWING SPEED SETTING
Note: For RDE wersion is not the button Ê functional and we do not recommend to use buttons Ë
Í. Control the sewing with button Ì.
It is possible to set the sewing speed in
range 1000, 1300, 1600, 1700, 1800,
1900 and 2000 punctures of needle bar
(stitch=two punctures).
20
389
CT 20
Ready
100001 0
J
2
4
3
1
3 3
1800 1300
7
+
-
+
-
+
-
+
-
Ê Ê
Ê Ê
Ê Number of stitches, which are sewn by slow speed at
the beginning of a buttonhole- range 0-9 by buttons +
and -.
Ë Ë
Ë Ë
Ë Number of stitches, which are sewn by slow speed at
the end of a buttonhole- range 0-9 by buttons + and -.
Ì Ì
Ì Ì
Ì Sewing speed in the first and the second row of
stitches - range 1000 - 2000 by buttons + and - .
Í Í
Í Í
Í Sewing speed in the eye - range 1000 - 2000 by
buttons + and - .
9
20
389
CT 20
Ready
100001 0
J
2
1
01
1
20
389
CT
100001 0
J
3
1
0
2
3
4
6
7
8
9
5
15
CRL
ENT
2
1
2
20
389
CT 20
Ready
100002 0
J
1
2